Summary :
No alarms received by all OCs suddenly
Problem

the following was logged in syslog.log at problem happening time:


Oct 11 04:08:11 fmtemip vmunix: vxfs: NOTICE: msgcnt 4239 mesg 001: V-2-1: vx_nospace - /dev/vg00/lvol4 file system full (1 block extent)


this message indicates /tmp partition of the system is full.

 

Cause
the problem is due to no disk space in /tmp partition, so that TeMIP applications cannot create temporary files in /tmp.
Fix