Update events from SCOM and change their severity in OMi
Title :
Update events from SCOM and change their severity in OMi
Document ID :
KM00831613
Product - Version:
operations manager i ;
OS :
Updated :
Mon Apr 07 14:13:38 GMT 2014
Summary :
BSM connector for SCOM & BSM

 

 

Events with increasing severity from SCOM are only treated as duplicates but the severity in the event viewer is not adjusted to the values of the latest event. Can this be configured on the OMi side?

Solution
 Go to BSM : admin : Infrastructure Settings: Applications: Operations Management, Section: Duplicate Events Suppression Settings, Setting: Update Severity of Original Event.
It;s possible to choose between No update (default), use the severity of the new event, or use the most critical severity of the old and the new event.