Self-Solve Knowledge Search

Minimize Maximize
How to change QC synchronizer log from INFO to DEBUG
Title :
How to change QC synchronizer log from INFO to DEBUG
Document ID :
KM1049488
Product - Version:
quality center 10.00 ;
OS :
Updated :
Thu Feb 26 07:07:35 GMT 2015
Summary :
The document describes how to change QC synchronizer log from INFO to DEBUG to capture more details of the synchronizer transactions

How to change QC synchronizer log from INFO to DEBUG to capture more details of the synchronizer transactions.

By Default, the syncrhonizer logs are in INFO mode,

 

Solution

In order to change the log level to to Debug

Edit the file 'log4j.properties' located into this default sync server directory 'C:\Program Files\HP\Quality Center Synchronizer\dat\' (or '<sync server install directory>\dat\'). The level can be modified by changing the line with 'loglevel':
loglevel=DEBUG.